Simple Ventilation. Sophisticated Technology. Trilogy makes invasive and noninvasive home ventilation less complicated with a simplified user interface and Respironics' proven BiPAP technology for greater versatility. Its lightweight design and internal and detachable batteries make portability easier for patients on the go. Simplicity Light, versatile, and easy to use, Trilogy100 offers clinicians and patients one of life's most remarkable qualities - simplicity. Whether at home or in alternative care sites, the Trilogy100 portable volume and pressure support ventilator with BiPAP technology is made for adult and pediatric use. Offers Two Circuit Options Interchangeable active and passive exhalation porting blocks give clinicians the flexibility to choose the best available circuit and interface for patients. Its internal PEEP, combined with a single limb circuit, creates an uncomplicated application. Portability Trilogy100 has been designed with portability in mind. • Weighs 5 kg (11 lb.) • Includes 3-hour internal and 3-hour detachable batteries • Ability to connect to an external lead-acid battery DirectView Ventilation Management Software Trilogy100 provides ventilation data and prescription management through the use of an SD memory card.
Environmental Specifications
Temperature: 5°C – 40°C
Relative humidity: 15% – 95%
Atmospheric pressure: 110 kPa to 60 kPa
Physical Specifications
Weight: 11 lbs, 5 kgs
Size: 6.6"L x 11.2"W x 9.3"H (16.68 cm L x 28.45 cm W x 23.52 cm H)
Controls
Circuit types: Active with PAP, passive
Ventilation types: Volume control, pressure control, bilevel
Volume modes: AC, SIMV (w/PS), CV
Pressure modes: CPAP, S, S/T, T, PC-SIMV (w/PS)
IPAP: 4 – 50 cm H20
EPAP: 0 – 25 cm H20 for active circuits; 4 – 25 cm H20 for passive circuits
CPAP: 4 – 20 cm H20 for passive circuits
PEEP: 0 – 25 cm H20 for active circuits; 4 – 25 cm H20 for passive circuits
Pressure support differential: 0 – 30 cm H20
Measured Patient Parameters
Tidal volume: 50 – 2000 ml
Breath rate: 0 – 60 for AC mode, 1 – 60 for all other modes
Inspiratory time: 0.3 – 5.0 secs
Rise time: 1 – 6
Ramp start pressure: 0 – 25 cm H20 for active circuits; 4 – 25 cm H20 for passive circuits; 4 – 19 cm H20 in CPAP mode
Ramp length: Off, 5 – 45 minutes
Flex: Off, 1 – 3
Flow trigger sensitivity: 1 – 9 l/min
Flow cycle: 10% – 90%
Apnea rate: 4 – 60 BPM
Tidal volume: 0 – 2000 ml
Minute ventilation: 0 – 99 l/min
Leak rate: 0 – 200 l/min
Respiratory rate: 0 – 80 BPM
Peak inspiratory flow: 0 – 200 l/min
Peak inspiratory pressure: 0 – 99 cm H20
Mean airway pressure: 0 – 99 cm H20
Percentage patient triggered breaths: 0 – 100%
I:E ratio: 9.9:1 to 1:9.9
Alarms
Circuit disconnect: Off, 10 – 60 secs
Apnea: Off, 10 – 60 secs
High tidal volume: Off, 50 – 2000 ml
Low tidal volume: Off, 50 – 2000 ml
High minute ventilation: Off, .1 – 99 l/min
Low minute ventilation: Off, .1 – 99 l/min
High respiratory rate: Off, 4 – 80 BPM
Low respiratory rate: Off, 4 – 80 BPM